AC BTU Calculator: What Size Air Conditioner Do You Need?

Your space
What are you sizing?
sq ft
ft
Cooling capacity needed
30,000 BTU
2.5 tons · 20 BTU per sq ft base, mixed climate
Cooling
Tons (12,000 BTU each)2.5 tons
Nearest standard unit2.5-ton central system (30,000 BTU)
BTU per sq ft used20.0 BTU/sq ft after adjustments
Heating
Heat loss to cover (output)60,000 BTU/h
Furnace input at 95% AFUE63,200 BTU/h → 80,000 BTU furnace
Heat pump size (rated at 47 °F)5.0 tons
A 1,500 sq ft house in a mixed climate needs about 30,000 BTU of cooling (2.5 tons): a 2.5-ton central system (30,000 BTU).

Rule-of-thumb sizing: central and mini-split cooling at 16–24 BTU per sq ft by climate zone, window units from the Energy Star room-AC chart, each scaled for insulation (±10–15%), sun (±10%), ceilings above 8 ft, plus 600 BTU per person beyond two and 4,000 BTU for a kitchen; heating at 30–60 BTU per sq ft by zone. Good enough to check a quote or buy a window unit; a contractor should run an ACCA Manual J load calculation before installing central equipment.

Type the square feet, pick your climate (or your state) and the calculator returns the cooling BTU and tons, the nearest standard unit size, and the heating BTU and furnace rating for the same space — with the adjustments for sun, insulation, ceiling height, people and kitchens that the rules of thumb leave out.

Choose what you are buying — a window or portable unit for one room, a ductless mini-split for a zone, a central system for the house, or a furnace or heat pump — then enter the area and the conditions. The calculator applies the standard rule of thumb for that equipment and climate, adjusts it for insulation, sun, ceiling height, occupants and a kitchen, and rounds to the sizes manufacturers sell. The heating rows always show, so you can size a heat pump that does both jobs. Treat the result as a check on a contractor’s proposal, not a replacement for a Manual J load calculation on new central equipment.

How many BTUs do I need per square foot?

Figure 20 BTU per square foot of cooling for an average house in a mixed climate, 24 in a hot-humid one and 16–18 in a cold one — so a 1,500 sq ft house needs about 30,000 BTU (2.5 tons) in the Mid-Atlantic and 36,000 BTU (3 tons) on the Gulf Coast. One room sized for a window unit uses a different scale: 500 sq ft takes a 12,000 BTU unit, 1,000 sq ft a 18,000 BTU unit. Heating runs 30–60 BTU per square foot by climate.

A BTU (British thermal unit) is the heat needed to raise one pound of water by 1 °F; an air conditioner’s rating is how many BTUs it removes per hour, and a ton is 12,000 BTU/h — the melting rate of a ton of ice in a day. Window units are sold by BTU (5,000–24,000), mini-splits by BTU (9,000–36,000 per head) and central systems by the ton (1.5–5 in half-ton steps). Manufacturers do not make a 2.7-ton unit, which is why the tool rounds up to the next standard size and tells you how far above your number it lands.

Worked examples

  • 500 sq ft open-plan apartment, mixed climate, two people, average sun: Energy Star base 12,000 BTU for 450–550 sq ft → 12,000 BTU window or portable unit. With a kitchen in the room, add 4,000 → 16,000 → an 18,000 BTU unit.
  • 1,000 sq ft ranch, mixed climate, average insulation: 1,000 × 20 = 20,000 BTU → 2-ton central system (24,000 BTU).
  • 1,500 sq ft house in Houston (hot-humid), 9-ft ceilings, sunny: 1,500 × 24 = 36,000, × 1.125 for ceilings × 1.1 for sun = 44,600 BTU → a 4-ton system. Same house shaded with good insulation: 32,800 BTU → 3 tons. The envelope swings the answer by a full ton.
Apartment building facade with a window air conditioner in every window
Window units are sized by the Energy Star chart: 5,000 BTU for a 150 sq ft bedroom up to 24,000 BTU for 1,500 sq ft — bigger is not better, it is clammy. Photo: Berna / Pexels

Window and portable AC sizing chart (Energy Star)

The Energy Star chart below is the one printed on the side of the box at the hardware store. It assumes two people, 8-ft ceilings and average sun; the official adjustments are +10% for a very sunny room, −10% for a heavily shaded one, +600 BTU for each person beyond two, and +4,000 BTU if the unit serves a kitchen. Measure the area the unit will actually cool — an open doorway to a hall counts, a closed bedroom door does not.

Energy Star room air conditioner sizing chart with sun adjustments
Room areaBase BTUTonsSunny room (+10%)Shaded room (−10%)
100–150 sq ft5,000 BTU0.42 ton5,5004,500
150–250 sq ft6,000 BTU0.5 ton6,6005,400
250–300 sq ft7,000 BTU0.58 ton7,7006,300
300–350 sq ft8,000 BTU0.67 ton8,8007,200
350–400 sq ft9,000 BTU0.75 ton9,9008,100
400–450 sq ft10,000 BTU0.83 ton11,0009,000
450–550 sq ft12,000 BTU1.0 ton13,20010,800
550–700 sq ft14,000 BTU1.17 ton15,40012,600
700–1,000 sq ft18,000 BTU1.5 ton19,80016,200
1,000–1,200 sq ft21,000 BTU1.75 ton23,10018,900
1,200–1,400 sq ft23,000 BTU1.92 ton25,30020,700
1,400–1,500 sq ft24,000 BTU2.0 ton26,40021,600
1,500–2,000 sq ft30,000 BTU2.5 ton33,00027,000
2,000–2,500 sq ft34,000 BTU2.83 ton37,40030,600

Source: Energy Star room air conditioner buying guidance. Add 600 BTU per person beyond two who regularly occupy the room and 4,000 BTU for a kitchen. Portable units are rated two ways: the older ASHRAE figure on the box and the DOE/SACC figure, which is 30–50% lower and is the one to compare with this chart.

Portable units deserve a warning. A “12,000 BTU” portable is typically 6,500–8,000 BTU by the DOE test, because its single hose pulls conditioned room air out to cool the condenser and draws hot outside air in through the gaps. Size portables by the SACC number, prefer dual-hose models, and expect a window unit of the same rating to cool a room about half again as large. Mini-splits are rated honestly and run at 25–40% of a window unit’s electricity for the same cooling. Match any of these to the room with the room size calculator, which gives square feet and the BTU for every common room size.

What size central AC for a 1,500, 2,000 or 3,000 sq ft house?

Central systems are sized by the ton, in half-ton steps from 1.5 to 5, and the right number depends on the climate first and the house second. A 2,000 sq ft house is a 3.5-ton job in Florida, a 3-ton job in Virginia and a 2.5-ton job in Minnesota at average insulation; a tight 2010s house drops half a ton in any of them, and a leaky 1960s house with west-facing glass adds half a ton. The old rule of “one ton per 400 square feet” comes from pre-1980 houses in hot climates and oversizes most modern homes by a ton.

Outdoor air-conditioner condenser units on the exterior wall of a building
The condenser’s model number usually encodes capacity: “36” in a model code is 36,000 BTU, 3 tons; “48” is 4 tons. Photo: Iban Lopez Luna / Pexels
Central AC cooling load and tonnage by house size and climate zone (average insulation and sun, 8-ft ceilings)
House sizeHot-humidHot-dryMixedColdVery cold
800 sq ft19,200 · 2 ton17,600 · 1.5 ton16,000 · 1.5 ton14,400 · 1.5 ton12,800 · 1.5 ton
1,000 sq ft24,000 · 2 ton22,000 · 2 ton20,000 · 2 ton18,000 · 1.5 ton16,000 · 1.5 ton
1,200 sq ft28,800 · 2.5 ton26,400 · 2.5 ton24,000 · 2 ton21,600 · 2 ton19,200 · 2 ton
1,500 sq ft36,000 · 3 ton33,000 · 3 ton30,000 · 2.5 ton27,000 · 2.5 ton24,000 · 2 ton
1,800 sq ft43,200 · 4 ton39,600 · 3.5 ton36,000 · 3 ton32,400 · 3 ton28,800 · 2.5 ton
2,000 sq ft48,000 · 4 ton44,000 · 4 ton40,000 · 3.5 ton36,000 · 3 ton32,000 · 3 ton
2,400 sq ft57,600 · 5 ton52,800 · 4.5 ton48,000 · 4 ton43,200 · 4 ton38,400 · 3.5 ton
2,800 sq ft67,200 · 5+ ton61,600 · 5+ ton56,000 · 5 ton50,400 · 4.5 ton44,800 · 4 ton
3,200 sq ft76,800 · 5+ ton70,400 · 5+ ton64,000 · 5+ ton57,600 · 5 ton51,200 · 4.5 ton

BTU = sq ft × 24 / 22 / 20 / 18 / 16 by zone, rounded up to the next half-ton (minimum 1.5). Over 5 tons the house usually gets two systems or a zoned system. Multiply by 1.15 for poor insulation, 0.9 for good; 1.1 for a sunny, west-facing house.

Which state is which climate zone?

The zones follow the IECC/DOE climate map, simplified to one zone per state (the tool’s state picker uses this list). States that straddle zones — California’s coast versus the Central Valley, Texas’s Panhandle versus Houston, upstate versus downstate New York — should pick the zone that matches their summer, not the state line.

  • Hot-humid (Gulf, Southeast): Alabama, Arkansas, Florida, Georgia, Hawaii, Louisiana, Mississippi, Oklahoma, South Carolina, Texas.
  • Hot-dry (Southwest desert): Arizona, California, Nevada, New Mexico.
  • Mixed (Mid-Atlantic, Pacific NW, upper South): Delaware, District of Columbia, Kansas, Kentucky, Maryland, Missouri, New Jersey, North Carolina, Oregon, Tennessee, Virginia, Washington, West Virginia.
  • Cold (Northeast, Midwest, Mountain): Colorado, Connecticut, Idaho, Illinois, Indiana, Iowa, Massachusetts, Michigan, Nebraska, New York, Ohio, Pennsylvania, Rhode Island, South Dakota, Utah, Wisconsin.
  • Very cold (northern tier, Alaska): Alaska, Maine, Minnesota, Montana, New Hampshire, North Dakota, Vermont, Wyoming.

Existing equipment is the best check. If the house already has a 3-ton system that keeps up on the hottest day with the thermostat holding, 3 tons is right regardless of what any chart says; if it runs non-stop and loses ground after 3 pm, the house needs sealing and insulation before it needs a bigger unit. The HVAC sizing tool walks through the same decision with duct and equipment options, and the utility cost calculator shows what cooling costs by state.

Furnace size calculator: heating BTU per square foot

Heating is sized by heat loss, which depends on the winter design temperature far more than on square feet, so the per-square-foot factor doubles from the Gulf to the northern tier: 30 BTU per sq ft in hot climates, 40 in mixed, 50 in cold and 60 in very cold, for average insulation and 8-ft ceilings. A 2,000 sq ft house in Ohio therefore needs about 100,000 BTU/h of heat on the coldest night; the same house in Georgia needs 60,000.

Furnaces are labeled by input, not output. A 95% AFUE furnace rated 100,000 BTU input delivers 95,000 BTU of heat; an 80% furnace with the same label delivers 80,000. Divide the heat loss by the efficiency to get the input rating to buy, then round up to the sizes sold (40, 60, 80, 100, 120, 140 thousand BTU). Heat pumps are sized in tons like air conditioners, but their capacity falls as the outdoor temperature drops — a standard 3-ton heat pump makes about 3 tons at 47 °F and half that at 17 °F, which is why cold-climate models and backup heat strips exist.

Heating BTU per square foot by climate zone and furnace size for 1,500–2,500 sq ft (average insulation)
Climate zoneBTU per sq ft1,500 sq ft2,000 sq ft2,500 sq ft2,000 sq ft furnace at 95% AFUE (input → size)
Hot-humid (Gulf, Southeast)30 BTU45,00060,00075,00063,158 → 80,000 BTU
Hot-dry (Southwest desert)30 BTU45,00060,00075,00063,158 → 80,000 BTU
Mixed (Mid-Atlantic, Pacific NW, upper South)40 BTU60,00080,000100,00084,211 → 100,000 BTU
Cold (Northeast, Midwest, Mountain)50 BTU75,000100,000125,000105,263 → 120,000 BTU
Very cold (northern tier, Alaska)60 BTU90,000120,000150,000126,316 → 140,000 BTU

Heat loss = sq ft × factor; furnace input = heat loss ÷ AFUE, rounded up to the next standard size. Multiply by 1.15 for a poorly insulated house, 0.9 for a well-insulated one, and by ceiling height ÷ 8 for tall rooms. Design temperatures: about 30 °F for hot zones, 15 °F mixed, 0 °F cold, −15 °F very cold.

Oversizing a furnace is less damaging than oversizing an air conditioner but still wastes money: a 120,000 BTU furnace in a house that loses 60,000 runs in short bursts, stresses the heat exchanger and leaves rooms far from the thermostat cold. If a contractor proposes replacing “like for like,” ask for the load calculation — most furnaces installed before 2000 were sized by rule of thumb for an uninsulated house and are one or two sizes too big for the house as it is now.

Why an oversized air conditioner is a problem

An air conditioner sized a ton too big short-cycles: it hits the thermostat setting in 8–10 minutes and shuts off before the coil has run long enough to pull moisture out of the air. The house ends up at 74 °F and 60% humidity — cold and clammy — and the owner turns the thermostat down further, which costs more and still feels wrong. Short cycling also wears out the compressor (starts are the hardest moment of its life), and an oversized system needs oversized ducts that most houses do not have, so airflow is noisy and uneven.

Undersizing by a half-ton is a far smaller problem than most people fear. The system runs long cycles on the hottest afternoons of the year and may lose a degree or two for a few hours; the rest of the summer it dehumidifies properly and uses less electricity. ACCA’s Manual S, the equipment-selection standard, lets a contractor pick a unit from 95% up to 115% of the calculated cooling load (up to 125–130% for some heat pumps in cold climates) and no more. If two quotes differ by a ton, the smaller one is usually the one that did the load calculation.

Ductless mini-split outdoor unit mounted on a brick wall
Mini-splits modulate: a 12,000 BTU head can run at 3,000 BTU on a mild day, which sidesteps the short-cycling problem that fixed-speed units have. Photo: Natalie Dmay / Pexels

Mini-split sizing and multi-zone systems

Size a single-zone mini-split like a central system for the area it serves: 20–24 BTU per sq ft in warm climates, so a 1,500 sq ft open floor plan wants a 30,000–36,000 BTU (2.5–3-ton) single head, or more realistically two or three heads totaling that. Heads come in 6,000, 9,000, 12,000, 18,000, 24,000 and 36,000 BTU; a bedroom is a 6,000–9,000 BTU head, a living room 12,000–18,000. A head cannot cool through a closed door, so count rooms, not just square feet.

For a multi-zone system add up the heads and pick an outdoor unit rated for 80–100% of that total — manufacturers allow connecting heads up to about 130% of the outdoor unit’s capacity because the rooms never all peak at once, but running every head at full load on an undersized condenser is where complaints start. One 36,000 BTU outdoor unit with four heads (12 + 9 + 9 + 6 = 36,000) covers a typical 1,500–1,800 sq ft house in a mixed climate; hot-humid houses add a head or step the condenser up to 48,000. Inverter mini-splits also heat efficiently to about 5 °F (cold-climate models to −15 °F), so the heating rows in the calculator apply to them as well.

Manual J versus rules of thumb

Everything on this page is a rule of thumb: square feet times a factor, adjusted for the big variables. An ACCA Manual J load calculation instead models each wall, window, roof and floor with its orientation, insulation value and air leakage, the local design temperatures, the people and the appliances, and produces a sensible and a latent load for every room. It typically comes in 10–30% below a rule-of-thumb size for houses built after 1990, which is why contractors who skip it install bigger equipment than the house needs.

Ask for a Manual J whenever you replace central equipment, add a mini-split system, or finish an addition or basement; it costs $150–$400 as a stand-alone service, is free from contractors who do it routinely, and is required by code for new construction in most states. Use this calculator to sanity-check the result: if the Manual J says 2 tons and the chart says 3.5, something in the house — a wall of west glass, an uninsulated attic — is either missing from the model or is the thing to fix. For a finished basement or a new room, the room size calculator gives the area and a window-unit size; the HVAC sizing tool covers whole-house equipment choices and ductwork.

How this ac & btu calculator works and where the numbers come from

Central and mini-split cooling: square feet × zone factor (hot-humid 24, hot-dry 22, mixed 20, cold 18, very cold 16 BTU per sq ft) × insulation (poor 1.15, average 1.0, good 0.9) × sun (shaded 0.9, average 1.0, sunny 1.1) × (ceiling height ÷ 8 when above 8 ft), plus 600 BTU per person beyond two and 4,000 BTU for a kitchen; rounded to the next half-ton for central equipment (1.5–5 tons) or the next mini-split head size. Window and portable units: Energy Star chart base × a zone factor (1.15 hot-humid … 0.85 very cold) × the same adjustments, rounded to the next size sold. Heating: square feet × zone factor (30/30/40/50/60 BTU per sq ft) × insulation × ceiling factor; furnace input = output ÷ AFUE, rounded up to 40–140k BTU; heat pump tons = output ÷ 12,000 rounded up to a half-ton. State-to-zone mapping simplifies the IECC climate map to one zone per state.

Last reviewed November 6, 2026. Estimates only — verify local figures before you commit money.

Common questions

AC & BTU Calculator: FAQ

How many BTU do I need for 500 sq ft? +

About 12,000 BTU — a 12,000 BTU window unit or a 12,000 BTU (1-ton) mini-split in an average climate. Add 10% for a sunny room, 4,000 BTU if it includes a kitchen, and 600 BTU for each person beyond two; a shaded bedroom of 500 sq ft can get by with 10,000.

What size AC do I need for 1,500 sq ft? +

A 2.5-ton (30,000 BTU) central air conditioner in a mixed climate, 3 tons in a hot-humid one such as Texas or Florida, and 2 tons in the very cold northern tier (2.5 in the rest of the North), for a house with average insulation and 8-ft ceilings. Sunny exposure, 9-ft ceilings or a leaky old house each add about a half-ton.

How many BTU for 1,000 sq ft? +

About 20,000 BTU (a 2-ton central system or two mini-split heads) in a mixed climate, 24,000 BTU in a hot-humid climate and 18,000 in a cold one. For a single window unit serving an open 1,000 sq ft space, the Energy Star chart says 18,000 BTU.

What size mini-split for 1,500 sq ft? +

About 30,000 BTU in a mixed climate and 36,000 in a hot one — usually delivered as a multi-zone system with a 30,000–36,000 BTU outdoor unit and three or four heads (for example 12,000 for the living area and 9,000 or 6,000 per bedroom), because a single head cannot cool through closed doors.

How many BTU per square foot for air conditioning? +

About 20 BTU per square foot for central air in a mixed climate, rising to 24 in hot-humid regions and falling to 16–18 in cold ones; window units run 20–33 BTU per sq ft on small rooms per the Energy Star chart. Adjust ±10% for sun or shade and ±10–15% for insulation.

What size furnace do I need for a 2,000 sq ft house? +

About 80,000 BTU of heat output in a mixed climate (40 BTU per sq ft), 100,000 in a cold climate and 120,000 in a very cold one — which at 95% AFUE means buying an 80,000–100,000 BTU input furnace in the Mid-Atlantic and 100,000–120,000 in the upper Midwest. In the South 60,000 BTU is enough.

Is it better to oversize or undersize an air conditioner? +

Slightly undersized is better. An oversized unit short-cycles, fails to dehumidify and wears out faster; a unit a half-ton small runs long cycles on the hottest few afternoons and otherwise performs better and costs less. ACCA Manual S allows equipment from 95% to 115% of the calculated load.

How many tons is 36,000 BTU? +

3 tons. One ton of cooling equals 12,000 BTU per hour, so 24,000 BTU is 2 tons, 36,000 is 3 tons, 48,000 is 4 tons and 60,000 is 5 tons. Window units are labeled in BTU; central systems in tons.